Different values for the feedback resistor in the recommended FlexiForce circuit

Question: What is the effect of changing the value of the feedback resistor used in the circuit in the manual?

Answer: If you are using our recommended circuit, a feedback resistor at half the recommended 20 kΩ value will increase the range to about double its stated range (up to ~0-50 lbs from ~0-25 lbs). If you only interested in measuring forces up to 4.5kg (~10 lbs), you should double the feedback resistor (rather than halving it). A feedback resistor of about 40kΩ would decrease the dynamic range to about 0-12 lbs.