How do I connect a FlexiForce sensor after it has been trimmed?

Question: How do I connect a FlexiForce sensor after it has been trimmed?

 

Answer: If Tekscan trims the A201 sensors to two inches, four inches, or six inches, the sensor will come with three (3) male square pin connectors spaced at 0.1" (2.54mm). If you trim the sensor yourself, you will need to re-connect the sensor using one of two methods.  You can purchase staked pin connectors and a crimping tool, or you can use a conductive epoxy to adhere small wires to each conductor.