Example of a non-simultaneous occlusal contact sequence during mandibular closure into maximum intercuspation
Example of simultaneous occlusal contact sequence during mandibular closure into maximum intercuspation
New Software Features with Version 5.0
Icons related to view are available inside Movie Window
With the touch of a button you can now view percentage force per
tooth or divide arch into quadrants.
Zoom graph window - acts as a secondary graph which displays a magnified
view of the Main Graph window. This graph is permanently fixed to display 1.5 seconds and provides a high resolution view for more intuitive graph analysis.
Customizable arch - The arch is customizable to each
patient and can be done prior to taking the recording.
Link digital photos to T-Scan data for enhanced documentation
Mirroring - mirror/flip the left and right aspects of the
arch to match the view of your choice
and much, much, more!
Dynamic View - watch an "occlusal movie" (click open on prompt to view movie, and escape to exit).
In addition to looking at the different views of maximum intercuspal forces in a static
mode, you can also use the T-Scan to assess the dynamic aspects of an entire functional movement. You can
determine where the first contact is, and if it is early or premature.
This is possible because the T-Scan breaks a bite sequence into 0.01 second increments during occlusal loading.
The T-Scan sensor was the first developed in 1987 with the start of the company. Since then, Tekscan has continued to improve the sensor design through Research and Development to ensure for the most accurate and reliable data. Today, Tekscan is pleased offer our 4th generationT-Scan sensor.
Sensor thickness is only 100 microns- no interference with natural bite.
Sensor is more durable than ever!
The disposable sensor can be reused for ~15-25 recordings.
The 4th generation sensor has no shelf-life date on the sensor- you can use them when you need them.
50% reduction of inactive area in the 4th generation sensors as compared to generations 1-3.
BioEMG-T-Scan Integration Module: The T-Scan III-BioEMG Integration
Software synchronizes and integrates the data of the T-Scan III with electromyography data of BioResearch's
EMG unit (BioEMG). BioEMG measures muscular functions of the head and neck while the T-Scan III shows
the force and distribution of teeth. Together, they give a comprehensive view of your patient's bite.
MatScan®:
Adds a pressure sensing floor mat capability to attain accurate and reliable gait, stance, balance, and pressure
readings available for the practitioner evaluating total body mechanics. Includes MatScan® software and floor mat
with sensor.
MatScan®/BioEMG Integration Module: This Integration software
synchronizes and integrates the clinical data of Tekscan's MatScan with the electromyographic data of BioResearch's
EMG unit. Together, they give a complete view of foot pressure, force, and weightbearing measurements and how they
relate to the rest and function performance of the muscles.
To Request More Information or a Demonstration- click here